Transmitter enables wireless access to plant data. Oct 23 2007-
Rosemount 702 wireless discrete transmitter allows access to data on plant performance and safety and is fully compatible with existing smart wireless networks. Applications include level and environmental spill prevention, personnel safety, and plant equipment status. It is an extension of PlantWeb® digital plant architecture and supports variety of non-powered switch types, with single- or dual-channel capacity, and is hazardous area-approved.
Remote Automation Controller uses Smart Wireless technology. Aug 22 2007-
With native communications capability for integration of wireless field networks, ROC800-Series Remote Operations Controller promotes remote asset management as well as maintenance efficiency. Centralized access helps users enhance safety and minimize risk of dangerous environments. Allowing communication with instrumentation at wellheads, pipelines, and other remote sites, product extends predictive intelligence of PlantWeb® digital architecture into remote oil and gas locations.
Software provides vibration analysis for rotating machinery. Jul 16 2007-
Featuring asset-centric interface, AMS Suite: Machinery Health(TM) Manager v5.0 provides users of CSI vibration data collectors with continuous online monitoring and IR thermography technology. Based on Internet Explorer browser, Machine History Viewer provides graphical display of machine health from any locations having access to Internet. Data Transfer Module allows users to electronically transmit vibration routes and data from one location to another.
CPUs offer upgrade path for SCADA applications. Apr 27 2007-
Models CW_35 and CW_31 CPUs offer upgrade path to the Bristol ControlWave® architecture, allowing existing Network 3000 customers to maintain investment in I/O, wiring, communication infrastructure, and application program development. ControlWave architecture cards support all commonly used analog, discrete and counter I/O cards, as well as modems and radios currently installed in RTUs. Communication compatibility is maintained through use of BSAP and Modbus protocols.
Software helps optimize control loop performance. Mar 14 2007-
Featuring adaptive tuning capabilities made possible with embedded learning algorithms, DeltaV(TM) InSight provides companies with integrated application for monitoring, analyzing, diagnosing, and improving control loop performance. Solution automatically recognizes all input, output, and control blocks in system as well as new blocks as they are added. It will also recommend tuning and maintenance improvements and adapt to changing process conditions.
Web-based Software promotes critical asset management. Feb 20 2007-
AMS(TM) Asset Portal(TM) v2.5 lets users capture asset information from range of internal sources and customize how data is used. Consolidating field-generated data into single meaningful view, it can produce snapshot of predefined plant areas' health, graphically summarize asset health, as well as save and filter information. Software also supports on-demand polling of data sources and enables export of asset data to reporting tools for problem asset report creation.
Liquid Analysis Platform allows single or dual inputs. Dec 20 2006-
Suited for OEM and liquid analysis applications, Model 1056 Single/Dual Input analyzer allows users to choose from combination of measurements such as pH/ORP/ISE, resistivity/conductivity, chlorine, oxygen, and temperature. Backlit LCD can display 4 process variables or diagnostic parameters simultaneously. Designed with modular cards and removable connectors to aid reconfiguration in field, product also provides warnings when sensor/instrument does not perform to specification.
Transmitter tracks equipment health using HART® protocol. Dec 19 2006-
Embedded in Rosemount 3051S Series pressure transmitter, ASP(TM) Diagnostics Suite provides tools for troubleshooting, detecting, and preventing abnormal situations. Statistical process monitoring technology warns of abnormal process or equipment conditions such as plugged impulse lines and changes in fluid composition. Suite also offers time-stamped variable logging and process alert capabilities to detect/record transient events or conditions outside specified limits of transmitter.
Orifice Fitting conforms to API 14.3, AGA 3, and ISO 5167. Dec 8 2006-
Daniel® Senior® Model 2000(TM) Orifice Fitting is designed with greaseless isolation valve that provides bubble tight seal, to reduce personnel exposure to pipeline content. Operation up-time is increased and maintenance reduced, by use of plate release mechanism that helps remove stuck plate carrier from metering position. Standard o-rings allow for reusability, while retractable locking pin enhances safety of operation.
Mezzanine Card is suited for signalling applications. Nov 24 2006-
With mid-size AdvancedMC form factor, Model KosaiPM enables addition of control and packet processing capability to AdvancedTCA and MicroTCA systems. Hot-swappable product features Pentium M processor operating up to 1.8 GHz, 2 MB of Level 2 cache, 2 GB of DDR SDRAM with ECC, and USB 2.0 and RS-232 interfaces. Module also has on-board storage interface, PCI Express and dual Gbit Ethernet interfaces, and 1 GB of flash memory.
|